A study of the hearing status in the contralateral healthy ear of patients with chronic otitis media following mastoidectomy surgery in a tertiary care hospital, Kerala, India

Authors

  • Anoop Varghese Kuruvilla Department of Otorhinolaryngology, Amala Institute of Medical Sciences, Thrissur, Kerala, India
  • Sumam Paul Vazhappilly Department of Otorhinolaryngology, Amala Institute of Medical Sciences, Thrissur, Kerala, India

DOI:

https://doi.org/10.18203/issn.2454-5929.ijohns20220464

Keywords:

High frequency, Drill, Sensory-neural hearing loss, Mastoidectomy

Abstract

Background: Bone drilling and suction during surgeries, exposes cochleae to noise of markedly high levels, temporal bone vibrations to high speeds of drill bits. Variations in burr type and drilling duration can determine extent of noise generated. These may affect cochlea and hearing status of a patient. This study tries to identify hearing loss if any, in the apparently healthy contralateral ear and, the effect of various drill parameters on hearing status in patients with chronic otitis media following mastoidectomy surgery.

Methods: Study done using proforma, clinical examination data from operation theatre during surgery and audiology department. Pure Tone Audiometry of apparently healthy contralateral and diseased ears in patients done before surgery, within 24 hrs and 72 hrs after surgery.

Results: Out of 161 patients ,12 patients (7.45%) developed hearing loss post operatively. The mean duration of drilling with cutting burr in the 12 patients with hearing loss was 28 minutes 20 seconds (SD: 1.72) and for diamond burr was 25 minutes and 26 seconds (SD: 2.06). Among the patients with hearing loss, four had multiple frequencies affected (33.3%). There was a statistically significant relation in type of drills used in surgery and hearing loss (p<0.001). In 10 Out of 12 patients, the hearing loss post-surgery, (83.3%) reverted to normal within 72 hrs.

Conclusions: A positive correlation exists between, transient sensorineural hearing loss that develops post-surgery with the various type of drills used for surgery, which reverted to pre-operative hearing levels within 3 days.

 

Author Biography

Sumam Paul Vazhappilly, Department of Otorhinolaryngology, Amala Institute of Medical Sciences, Thrissur, Kerala, India

Department of Otorhinolaryngology,

Assistant Professor

References

Robertson D, Johnstone BM, McGill TJ. Effects of loud tones on the inner ear: a combined electrophysiological and ultrastructural study. Hearing Res. 1980;2(1):39-53.

Ito T, Kubota T, Furukawa T, Matsui H, Futai K, Hull M et al. The Role of Powered Surgical Instruments in Ear Surgery: An Acoustical Blessing or a Curse?. Applied Sci. 2019;9(4):765.

Baradaranfar MH, Atighechi S, Dadgarnia MH, Jafari R, Karimi G, Mollasadeghi A et al. Hearing status in neonatal hyperbilirubinemia by auditory brain stem evoked response and transient evoked otoacoustic emission. Acta Medica Iranica. 2011;109-12.

Goyal A, Singh PP, Vashishth A. Effect of mastoid drilling on hearing of the contralateral ear. The J Laryngol Otol. 2013;127(10):952.

Pal SK. Evaluation of the effect of drilling on hearing in ear surgery. Bengal J Otolaryngol Head Neck Surg. 2014;22(2):22-5.

Tos M, Trojaborg N, Thomsen J. The contralateral ear after translabyrinthine removal of acoustic neuromas: Is there a drill-noise generated hearing loss?. The J Laryngol Otol. 1989;103(9):845-9.

Migirov L, Wolf M. Influence of drilling on the distortion product otoacoustic emissions in the non-operated ear. ORL. 2009;71(3):153-6.

Foss I, Flottorp G. A comparative study of the development of hearing and vision in various species commonly used in experiments. Acta Oto-Laryngologica. 1974;77(1-6):202-14.

Domenech J, Carulla M, Traserra J. Sensorineural high-frequency hearing loss after drill-generated acoustic trauma in tympanoplasty. Archives of oto-rhino-laryngology. 1989;246(5):280-2.

Zou J, Bretlau P, Pyykkö I, Starck J, Toppila E. Sensorineural hearing loss after vibration: an animal model for evaluating prevention and treatment of inner ear hearing loss. Actaoto-laryngologica. 2001;121(2):143-8.

Urquhart AC, McIntosh WA, Bodenstein NP. Drill‐generated sensorineural hearing loss following mastoid surgery. The Laryngoscope. 1992;102(6):689-92.

Lee HK, Lee EH, Choi JY, Choi HS, Kim HN. Noise level of drilling instruments during mastoidectomy. Yonsei Med J. 1999;40(4):339-42.

Downloads

Published

2022-02-24

Issue

Section

Original Research Articles